Page 375 - ZF-Catalog-ZSi-Foster-08-19-R3
P. 375

Quick Coupling Installation
  Be Safe When Installing Quick Couplings Installation Of Reusable Hose Couplings
  1 Trim the end of the hose as square as possible.
3 Mark the point of full hose insertion depth with a piece of tape.
5 Add a bit of lubricant to the reusable hose barb before inserting into the ferrule.
7 Tighten reusable hose barb into ferrule ensuring hose stays completely inserted.
2 Insert Hose completely into ferrule and make note of how deep the hose goes.
4 Verify tape line is correct for full insertion.
6 Turn reusable hose barb into ferrule ensuring hose stays completely inserted.
      ZSi-Foster Engineering Catalog
– 375 –
8 Completed connection, Use marker applied in step [3] to ensure hose is completely inserted.
           Indexes Technical Data Hoses & Fittings Fittings & Accessories Blow Guns & Accessories Hydraulic QD Pneumatic QD






















































































   373   374   375   376   377