Page 257 - ZSi-Foster Engineering Catalog - Electronic Version 2
P. 257

Z-Clamp & Beta Adapter Installation
   Installation of Z-Clamps
Z-Clamps are installed in much the same manner as Beta Clamps. The weld studs are welded onto exiting structure and the clamp assembled onto them.
Installation of Beta Adapter
Beta Adapters are installed in much the same manner as Beta Clamps. The weld plate is welded onto existing structure and the Beta cushion and adapter is assembled onto it.
(1) Weld Studs to Supporting Steel
(1) Weld Plate to Supporting Steel
 (2) Place the lower Z-Clamp Frame Onto the Studs
   (3) Attach the Stacking Bolts to the Frame and then Insert the Desired Adapters
(2) Push Bottom Half of Clamp Onto Plate
(4) Add Top Cushion
   (3) Insert the Desired Adapter
    (4) Bolt Top Frame Onto
the Bottom to Secure Assembly
          Z-Clamp & Beta Adapter Optional Adapters
FEMALE JUNCTION O-RING FACE SEAL ADAPTER
(5) Add Top Plate and Bolt into Position
37° FLARE MALE JUNCTION ADAPTER
RUBBER SPLIT BUSHINGS